Duct Damper Safe

Product NameDuct Damper Safe
MaterialPlastic,ABS,PVC or other material
ColorWhite or custom color
StandardChina standard
SizeCustomized
MOQ10
PackagingStandard packaging
Delivery30day
  • HVAC Air Distribution

    In addition require the contractor to provide a minimum 144 sq. inches of access to the damper on ductwork larger than 14″ on one side. On smaller ductwork specify a 2 ft. long removable section of duct for access. Automatic Dampers. A safe means of maintenance access shall be provided for all duct damper actuators and damper access doors.

    Ask For Quote Details
  • MAINTENANCE AND TESTING OF FIRE/SMOKE DAMPERS

    o Where the size of the duct permits, access doors should be at least 18 inches x 16 inches in size. o Where fire dampers are too large to allow them to be reset and the fusible link replaced from outside the duct, the access doors should be increased to at least 24 inches x 16 inches in size to allow a person to enter the duct.

    Ask For Quote Details
  • HVAC Air Distribution

    In addition require the contractor to provide a minimum 144 sq. inches of access to the damper on ductwork larger than 14″ on one side. On smaller ductwork specify a 2 ft. long removable section of duct for access. Automatic Dampers. A safe means of maintenance access shall be provided for all duct damper actuators and damper access doors.

    Ask For Quote Details
  • What is the Difference Between a Fire / Smoke Damper and a

    A fire damper will close only when there is high heat in the duct near the damper. Hi Douglas,If there is a failure of the system, the damper fails in the closed position - the damper is "Fail-Safe". Because the motor used to keep the damper open is always turned on, you can put your hand on the motor and feel that it is warm. If the motor

    Ask For Quote Details
  • Ventilation damper, Lindab Air duct systems, Ventilation

    Dampers are installed in ventilating equipment for various purposes, such as: regulating, shut off, motorized, constant flow and variable flow. Flow meters are used to decide airflow rate in a duct system.

    Ask For Quote Details
  • Our quick guide to smoke/fire dampers

    Fire dampers. A fire damper's primary function is to maintain compartmentation and prevent, or impede, the spread of fire through the ventilation ductwork. Fire dampers are designed to allow air to flow through in normal operation but then shut suddenly with a thermal release mechanism at the outbreak of a fire, and are designed to failsafe

    Ask For Quote Details
  • Sample Engineering Specification for Lindab Safe®

    fittings will be accepted. The use of duct taps is unacceptable. E. All volume and balancing dampers shall be Lindab Safe® type DRU, DSU or DTU as specified on the contract documents. Damper shall be fitting sized to slip into the spiral duct with a double lipped, U-profile, EPDM rubber gasket. Damper shall have the following features: a.

    Ask For Quote Details
  • TECHNICAL MANUAL

    Fire dampers that incorporate a fusible link (thermal device) are designed to close when triggered by the elevated temperatures within a duct in the event of fire. This precludes their use in Smoke Extract or Pressurisation systems as the dampers, once activated, would prevent these systems from fulfilling their intended function.

    Ask For Quote Details
  • TOPIC: Combination Fire/Smoke Damper Release Devices

    mally closed fail safe feature). A fusible link or fuse rod lets the damper close too fast when it releases (instantaneously) which has the potential for costly duct disruption or collapse. The EFL and PFL are controlled closure devices which allow the damper to close in 3 to 10 seconds rather than instantaneously.

    Ask For Quote Details
  • Removeable Duct Section

    As a building owner, the new fire and smoke damper inspection requirements create further challenges for your HVAC system. NFPA 80(2013) 19.2.3 access states dampers equipped with fusible links, internal operators or both shall be provided with an access door that is not less than 12 inches (305mm) square or provided with a removable duct section.

    Ask For Quote Details
  • IR8

    not comply with the Safe Drinking Water Act, which requires that products used in anyDampers do not close completely Specs Duct Size: Material: Galvanized Steel Type:

    Ask For Quote Details
  • Method Statement For Installation of HVAC Supply, Return

    Joints of Volume Control Dampers (VCD's), Fire Dampers and duct work shall be sealed with approved sealant. 7.23 Access doors shall be provided at all fire damper locations. 7.24 All insulated and uninsulated duct work passing through the openings in walls inside the building shall be provided with a G.I Sheet Sleeve

    Ask For Quote Details
  • FIRE AND SMOKE DAMPER OPERATION OPTIONS

    duct temperature has not exceeded the high limit. The High Limit Temperature Sensor pre-vents the damper from reopening when duct temperature is above damper's UL555S degradation test temperature of 250°F/121°C or 350°F/177°C. Upon ces-sation of the fire conditions, the damper can be reopened by pressing the RESET button located on the

    Ask For Quote Details
  • Rossi Air Flow, Inc. – HVAC Air Flow Products

    1. Drill 3/4" holes on each side of your sheet metal sleeve and click the Snap-In Bushings into place. 2. Holding the blade in position, pass the 3/8" square bar through the bushings and channel in the blade. 3. Spotweld or rivet the regulator in place, making sure the handle and blade are in corresponding positions. 4.

    Ask For Quote Details
  • Tertiary Air Duct Dampers | Products & Suppliers | Engineering360

    Air hose and air duct hose is used in pneumatic systems and controls, or as supply linessafe actuators for industry and are used on valves, dampers and air handling louvers.

    Ask For Quote Details
  • Double louver damper

    Title: United States Patent 4493342 Abstract: A double louver damper for use in a duct system conveying hot gases and particles in order to permit safe entry to be made therein when

    Ask For Quote Details
  • Air Duct Solutions

    Welcome to Air Duct Solutions. At Air Duct Solutions we understand we now live in a world fully capable of controlling our indoor environments and maintaining those environments at comfortable levels efficiently. Whether it is your home, office, school, manufacturing facility, or government building; we believe technology and equipment

    Ask For Quote Details
  • Perfect Gas Sealing | Guillotine Dampers | Flowseal

    Although this is a Total Isolation damper it cannot be perceived as Man-Safe due to the possibility of purge air supply failure. General Design Flowseal guillotine dampers can be fabricated for any duct size, circular or rectangular and can be fitted to a vertical duct or to a horizontal duct with the gate entry from the top or bottom of duct.

    Ask For Quote Details
  • Air Duct Damper: What It Is And How To Install It – Smarthome

    With a manual duct damper, there's a physical handle located outside the duct for you to manipulate. Automatic air duct dampers come with pneumatic or electric motors. You can control them with either a smart thermostat or a fully automated system throughout the whole building.

    Ask For Quote Details
  • air damper valve suppliers and air damper valve manufacturers info

    1.air damper valve actuator 2. compact and safe 3. heat resistance 4. patented product 5.air duct valveYuyao East ventilation Engineering Company Limited is specialized in

    Ask For Quote Details
  • Explosion proof electric ATEX actuators, sensors

    All devices available for hazardous locations or safe area (depending on application and type) 90° actuators for air-, fire-/smoke dampers, ball valves, throttle valves ExMax zone 1, 2, 21, 22 / RedMax zone 2, 22

    Ask For Quote Details


Our Location

Contact Us

Boda Aluminum Products Co.,LTD

Address: Jingjiang, Taizhou City
Jiangsu Province, China
Zip code - 214500
Telephone: +86 18262317598