  • BUILDING AIR INTAKE AND EXHAUST DESIGN

    Building General Exhaust Air. General indoor air that is ex-hausted normally contains elevated concentrations of carbon diox-ide, dust, copier toner, off-gassing from materials, cleaning agents, and body odors. General exhaust air s hould not be allowed to reenter the building without sufficient dilution. Stagnant Water Bodies, Snow, and Leaves.

    Ask For Quote Details
  • Eliminators , Louvers & Air Diffusers – S.M Extrusions

    PVC Mist Eliminators / Louvers for Humidification and Ventilation systems. A wide range of PVC Eliminators and Louvers for use in Air washers, Humidification plants, Ventilation systems, Air handling units, Cooling towers, Cooling coils and such diverse applications to serve Textile, Cement, Power, Coal and many other industries.

    Ask For Quote Details
  • UFGS 23 00 00 (15895) Air Supply, Distribution

    2.7.5.8 Security Return and Other Air Registers Except in Cells 2.7.5.9 Security Supply Air Registers in Cells 2.7.5.10 Security Return and Other Type Air Registers in Cells 2.7.6 Louvers 2.7.7 Air Vents, Penthouses, and Goosenecks 2.7.8 Bird Screens and Frames 2.7.9 Radon Exhaust Ductwork 2.8 AIR SYSTEMS EQUIPMENT 2.8.1 Fans

    Ask For Quote Details
  • Venting a Server Closet (The Right Way)

    This fan will pull about 25 watts and continuously exhaust air from the room, even when the A/C or Furnace is idle. Even though the fan is designed to be installed either at the return vent, or at the A/C unit by default, I opted to install the blower about three to four feet from the rooms return air vent inline with the ductwork.

    Ask For Quote Details
  • Comparing Economizer Relief Systems

    Ł Larger louver size. Relief louvers and dampers usually need to be larger than those used with fan-powered relief systems to minimize pressure drop.This causes the relief fan to exhaust outdoor air rather than building air so building pressure will rise. This, in turn, causes the capacity control device on the relief fan to exhaust

    Ask For Quote Details
  • Combustion Air Requirements:The Forgotten Element In

    The outside air openings may be protected by louvers or grills. However, the blocking effect of the louver or grill must be considered, and sizing must be done based on its free area. If a protective mesh is used, the mesh must be no smaller than 0.25 inch to minimize dirt build-up or obstruction.

    Ask For Quote Details
  • How To Size Greenhouse Fans & Shutters | Rimol Greenhouse

    To calculate shutter size, take your total CFMs and divide by 600. The number is an air velocity number that means that the air is traveling at 600 feet per second. Smaller shutter openings will create a higher air velocity and create more of a breeze; larger openings will create a lower air velocity and create less of a breeze.

    Ask For Quote Details
  • Understanding Muffler Design and Sound Absorption

    This vibration, or pulses of high and low are pressure, move through the air at the rate of a mile in five-seconds on the average – commonly referred to as “the speed of sound.” In an internal combustion engine, these pulses are created when the exhaust valve opens and the hot gas from the combustion chamber enters the exhaust system.

    Ask For Quote Details
  • 7. COOLING TOWER

    Air inlet: This is the point of entry for the air entering a tower. The inlet may take up an entire side of a tower–cross flow design– or be located low on the side or the bottom of counter flow designs. Louvers: Generally, cross-flow towers have inlet louvers. The purpose of louvers is to equal-

    Ask For Quote Details
  • Galvanized metal roofing Building Supplies | Bizrate

    wire Hot Dipped Galvanized RING shank Coil Roofing Nails Wire Collated 160/Coil 45Roof Louvers are a type of attic exhaust vent that make up half of a balanced attic

    Ask For Quote Details
  • Natural Ventilation | WBDG

    The two can be combined by having a cool tower deliver evaporatively cooled air low in a space, and then rely on the increased buoyancy of the humid air as it warms to exhaust air from the space through a stack. The cool air supply to the space is pressurized by weight of the column of cool air above it.

    Ask For Quote Details
  • Classroom Unit Ventilator Accessories

    • Gravity relief damper (exhaust stale air naturally from the class-room). • Side wall power exhaust system (exhaust stale air mechanically from the classroom). • and Unit ventilator energy recov-ery system (treats and filters in-coming fresh air into the classroom as well as exhausts stale air from the classroom).

    Ask For Quote Details
  • Building Codes and Indoor Air Quality

    condition the indoor air. This latter function-- reducing air change rates—puts energy conservation in conflict with providing adequate indoor air quality if it provides insufficient outdoor air to dilute indoor-generated contaminants, or insufficiently replace air exhausted by exhaust fans, clothes dryers and combustion equipment.

    Ask For Quote Details
  • Info

    In all areas, exhaust vents should be at least 1 foot above roof surface. Exhaust vents must be protected against rain and equipped with back flow prevention features (e.g., flap dampers). Exhaust vents must not be allowed to be obscured or hidden by vegetation. Vegetation must not be allowed to grow within 3 feet of an exhaust vent.

    Ask For Quote Details
  • Fan CFM Calculator– Industrial Fans Direct

    This fan calculator is typically used to calculate the CFM or cubic feet per minute of air exchange that may be desired in a building. Whether exhausting air or bringing fresh air into a structure, the calculation produced should help to figure out the size of fan(s) required to accomplish the air exchanges needed.

    Ask For Quote Details
  • Ducting AccessoriesEspar Heaters and Parts

    Add Multi Inlet screen - 5.25 in This safety grille is used when return ducting is in place. It can be used with 75mm (3in.), 90mm (3.5in) and 100mm (4in) ducting.

    Ask For Quote Details
  • VF Shutter Exhaust Fan 36 inch 10100 CFM Direct Drive

    The Wall Master Exhaust Fans offer high volume output, smooth and efficient operation in a compact, low profile heavy-duty fan housing. The heavy duty 18 gauge galvanized low profile housing is strong, compact, easy to install and comes totally assemble. Aluminum shutters include tie bars to prevent the shutter from fl

    Ask For Quote Details
  • GENERATING SETS INSTALLATION GUIDE

    size of the exhaust piping should be increased to suit. The same comments apply for the hot air outlet ducting and any other engine/alternator connections, must be of the flexible type, i.e. fuel pipes and electrical connections. The daily fuel tank is supplied with fuel from a bulk tank and not the day tank housed remotely from the engine room.

    Ask For Quote Details
  • Fan CFM Calculator– Industrial Fans Direct

    This fan calculator is typically used to calculate the CFM or cubic feet per minute of air exchange that may be desired in a building. Whether exhausting air or bringing fresh air into a structure, the calculation produced should help to figure out the size of fan(s) required to accomplish the air exchanges needed.

    Ask For Quote Details
  • Some Like It Hot…Your Compressor Room Doesn't – Kaeser

    In the summer, the warm air can be ducted outdoors. 3. Exhaust Fan: Ancillary equipment in a compressed air system, such as refrigerated dryers, can require significant amounts of cooling air. If this is the case, an exhaust fan may be required to provide additional airflow. 4.

    Ask For Quote Details
  • China Wall Mount Exhaust Fan, Wall Mount Exhaust Fan

    China Wall Mount Exhaust Fan manufacturers - Select 2021 high quality Wall Mount Exhaust Fan products in best price from certified Chinese Electric Fan, Industrial Fan suppliers, wholesalers and factory on Made-in-China.com

    Ask For Quote Details


Our Location

Contact Us

Boda Aluminum Products Co.,LTD

Address: Jingjiang, Taizhou City
Jiangsu Province, China
Zip code - 214500
Telephone: +86 18262317598
E-mail: [email protected]